Why does the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP cannot be assigned to Bank 3A or 3D when using the Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices? - Why does the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP cannot be assigned to Bank 3A or 3D when using the Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices? Description Due to the limitation of the Intel® Stratix® 10 1ST040*, 1SG040*, and 1SX040* devices, you will see hardware failure if you assign the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP to Bank 3A or 3D in the Intel® Quartus® Prime Pro Edition Software version 19.3. Resolution To avoid this problem, do not assign the PHY Lite for Parallel Interfaces Intel® Stratix® 10 FPGA IP to Bank 3A or 3D for Intel® Stratix® 10 1ST040*, 1SG040* and 1SX040* devices. Custom Fields values: ['novalue'] Troubleshooting 1507429050 False ['PHY Lite for Parallel Interfaces Stratix® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 19.3 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-10-16