Why cant I run the Transceiver Toolkit Auto sweep feature for VOD values of lower than 6 in the Quartus II Software, versions 12.0 and later? - Why cant I run the Transceiver Toolkit Auto sweep feature for VOD values of lower than 6 in the Quartus II Software, versions 12.0 and later?
Description In the Quartus® II software versions 12.0 and later, the Transceiver Toolkit Auto sweep feature restricts the sweeping of transceiver PMA parameters to approved combinations. VOD values of less than 6 may not produce an optimal eye and are restricted. Resolution To work around this restriction you can increase the minimum VOD to 6 or higher. Alternatively you can test VOD values lower than 6 using the manual selection mode.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
12.0
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document