Are Stratix® 10 GX 2800 H-Tile -AS devices impacted by the Power-on Configuration issue? - Are Stratix® 10 GX 2800 H-Tile -AS devices impacted by the Power-on Configuration issue? Description Are Stratix® 10 GX 2800 H-Tile -AS devices impacted by the Power-on Configuration issue? Resolution No, Stratix® 10 GX 2800 H-Tile Advanced Security (with the suffix -AS) devices are not impacted by intermittent configuration failures which may occur if the FPGA is not configured with at least 256 kB of configuration data within 18 seconds after completion of the power-up sequence. Refer to the Stratix 10 GX Production Device Errata for the list of impacted devices. Custom Fields values: ['novalue'] Troubleshooting 1807393135 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] No plan to fix 19.1 ['Stratix® 10 GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2024-11-28