Why do the EMIF Traffic Generator 2.0 configuration and status registers reset to their default values when the WORM mode is enabled? - Why do the EMIF Traffic Generator 2.0 configuration and status registers reset to their default values when the WORM mode is enabled? Description Due to a problem in the Quartus® Prime Pro Edition Software version 20.1, the EMIF Traffic Generator 2.0 (TG2) configuration and status registers (CSR) reset to their default values when Write Once Read Many (WORM) mode is enabled and a data mismatch is encountered. Note that the WORM mode is disabled by default. Resolution This problem is fixed starting with the Quartus® Prime Pro Edition Software version 20.4. Custom Fields values: ['novalue'] Troubleshooting 22012642746, 14012502601 False ['External Memory Interfaces Stratix® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 21.1 20.1 ['Agilex™ 7 FPGAs and SoCs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-11-28