Do I need a pull-up resistor on the DATA configuration input signal of my Stratix, Stratix GX, or Cyclone device? - Do I need a pull-up resistor on the DATA configuration input signal of my Stratix, Stratix GX, or Cyclone device?
Description A pull-up resistor to Vccio is recommended on the DATA input signal if the only configuration scheme implemented on the board is Passive Serial using a download cable (ByteBlasterMV, ByteBlaster II, or MasterBlaster). This pull-up resistor prevents the DATA input from floating when the cable is not connected to the board. If the board implements other configuration schemes (configuration device or processor based), the pull-up resistor is not required. In these scenarios, the configuration device or processor should hold the DATA input at a valid TTL logic level.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['novalue']
novalue
novalue
['Stratix® FPGAs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document