Internal Error: Sub-system: RCOMP, File: /quartus/comp/rcomp/rcomp_mgr_impl.cpp, Line: 320 - Internal Error: Sub-system: RCOMP, File: /quartus/comp/rcomp/rcomp_mgr_impl.cpp, Line: 320
Description Due to a problem in the Quartus® Prime Pro Edition Software version 22.1 or earlier, you may see this internal error when you try to compile the design. This is caused by the Quartus® Prime Pro Edition Software trying to reach the Cloud Notification Center that has been marked EOL (End of Life). Resolution To avoid this problem in the Quartus® Prime Pro Edition Software, follow the steps below: 1. Go to Tools, Options, Internet Connectivity, and turn off the Notification Center feature. 2. In your quartus2.ini file , remove any assignment that will try to reach the Notification Center . The quartus2.ini file is located at: For Windows OS, go to C:/user/<username>/ For Linux OS, cd to home/<user>/.altera.quartus Example of cloud related setting that need to be removed: CLOUD_SEND_END_FLOW_NOTIFICATIONS = on CLOUD_SEND_REPORTS = on CLOUD_SERVER = https://fpgacloud.intel.com CLOUD_TOKEN = <secret> CLOUD_USERNAME = <username> 3. In your .qsf file, remove any assignments that are tagged with dse_intenal . Example: set_global_assignment -name CLOUD_NOTIFY_GROUP_ID 23485 -tag dse_internal set_global_assignment -name CLOUD_NOTIFY_ENABLE ON -tag dse_internal This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 22.2.