SEVERE: AutoSweepControllerPMAAnalog constructor rbc failure - SEVERE: AutoSweepControllerPMAAnalog constructor rbc failure Description Due to a problem in the Quartus® II software version 10.0 SP1, this error may be generated when attempting to run an Auto-Sweep with the Transceiver Toolkit. Due to this problem, you may also see messages similar to: SEVERE: AutoSweepControllerPMAAnalog constructor rbc failure java.lang.Exception: ALTERA INTERNAL ERROR: RBC error code (2) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerJniInterface.get_legal_values(Native Method) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.initializeTXDictionaryTreeWithRBC(RuleBasedCheckerReconfigAnalogSolver.java:949) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.initializeTXDictionaryTree(RuleBasedCheckerReconfigAnalogSolver.java:915) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.getDictionaryTreeRoot(RuleBasedCheckerReconfigAnalogSolver.java:801) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.access./kdb00(RuleBasedCheckerReconfigAnalogSolver.java:776) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.solve(RuleBasedCheckerReconfigAnalogSolver.java:100) at com.altera.systemconsole.transceivers.internal.RuleBasedCheckerReconfigAnalogSolver.solve(RuleBasedCheckerReconfigAnalogSolver.java:95) at com.altera.systemconsole.transceivers.internal.AutoSweepControllerPMAAnalog.GenerateRbcTestCases(AutoSweepControllerPMAAnalog.java:805) at com.altera.systemconsole.transceivers.internal.AutoSweepControllerPMAAnalog.access./kdb00(AutoSweepControllerPMAAnalog.java:43) at com.altera.systemconsole.transceivers.internal.AutoSweepControllerPMAAnalog.run(AutoSweepControllerPMAAnalog.java:172) at com.altera.systemconsole.internal.core.SystemExecutor.run(SystemExecutor.java:318) at com.altera.systemconsole.internal.core.SystemExecutor.run(SystemExecutor.java:436) at com.altera.systemconsole.internal.core.SystemExecutor.run(SystemExecutor.java:207) at java.util.concurrent.ThreadPoolExecutor.runTask(Unknown Source) at java.util.concurrent.ThreadPoolExecutor.run(Unknown Source) at java.lang.Thread.run(Unknown Source) A patch is available to fix this problem for the Quartus II software version 10.0sp1. Download and install Patch 1.117 from the appropriate link below. Download the version 10.0 SP1 Patch 1.117 for Windows (.exe) Download the version 10.0 SP1 Patch 1.117 for Linux (.tar) Download the Readme for the Quartus II software version 10.0 SP1 Patch 1.117 (.txt) This problem is fixed beginning with the Quartus II software version 10.1. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2022-01-18

external_document