Why don’t I see transceiver simplex PHY instances in the Quartus® Prime Pro Edition Software Transceiver Toolkit when using the Cyclone® 10 GX FPGA, Arria® 10 FPGAs, or Stratix® 10 L or H-Tile FPGA devices? - Why don’t I see transceiver simplex PHY instances in the Quartus® Prime Pro Edition Software Transceiver Toolkit when using the Cyclone® 10 GX FPGA, Arria® 10 FPGAs, or Stratix® 10 L or H-Tile FPGA devices? Description Due to a bug in the Quartus® Prime Pro Edition Software v21.3 and earlier, you might not see transceiver PHY simplex instances in the Transceiver Toolkit when using Cyclone® 10 GX FPGA, Arria® 10 FPGAs, or Stratix® 10 L or H-Tile FPGA devices. This problem might occur if your Quartus® Prime Pro Edition Software design contains only simplex transceiver PHY instances. Resolution To work around this problem, you can instantiate a dummy duplex transceiver PHY instance and ensure that the Transceiver Native PHY IP Debug Master Endpoint (NPDME) option is enabled. This problem will be fixed in a future version of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 18018855503 False ['DisplayPort', 'HDMI', 'JESD', 'L-Tile H-Tile Transceiver Native PHY Stratix® 10 FPGA IP', 'Low Latency PHY IP', 'Transceiver Native PHY Arria® 10 Cyclone® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 25.1.1 19.1 ['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 GX FPGA', 'Stratix® 10 GX FPGA', 'Stratix® 10 MX FPGA', 'Stratix® 10 NX FPGA', 'Stratix® 10 SX FPGA', 'Stratix® 10 TX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2024-10-11

external_document