Why does the lane_act bus show incorrect link widths for my Stratix 10 H-tile Hard IP for PCI Express? - Why does the lane_act bus show incorrect link widths for my Stratix 10 H-tile Hard IP for PCI Express?
Description Due to a problem with the Hard IP for PCI Express* on the Intel® Stratix® 10 H-Tile Production devices, you will see incorrect encoding of the lane_act bus as shown in the following table: Actual Link Width lane_act value Link Width according to the user guide encoding x1 5'b1 0000 x16 x2 5'b0 0001 x1 x4 5'b0 0010 x2 x8 5'b0 0100 x4 x16 5'b0 1000 x8 Resolution To work around this problem, which only affects H-tile production devices, interpret lane_act using the first two columns in table above. This problem will be fixed by soft logic in a future Intel® Quartus® Prime software release.
Custom Fields values:
['novalue']
Troubleshooting
FB: 508093;
True
['Avalon-ST Stratix® 10 Hard IP for PCI Express']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
17.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document