How is config_data shifted into the scan chain block when dynamic reconfiguration is used in ALTDQ_DQS2 Megafunction? - How is config_data shifted into the scan chain block when dynamic reconfiguration is used in ALTDQ_DQS2 Megafunction? Description For Stratix® V GX and Arria® V GZ devices, the bitstream for config_data must be LSB first (from LSB to MSB). For Arria® V and Cyclone® V devices, the bitstream for config_data must be MSB first (from MSB to LSB). Resolution This information has been updated in ALTDQ_DQS2 IP Core User Guide version 15.1 and above. Custom Fields values: ['novalue'] Troubleshooting 2205755324 False ['ALTDQ_DQS2 v18.1'] ['novalue'] novalue novalue ['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs', 'Stratix® V FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2023-03-08