Why does a dialog box pop up stating “Another instance of System Console appears to be running with title: SystemConsole” when relaunching the F-Tile Transceiver Toolkit in the Intel® Quartus® Prime Pro Edition Software version 22.1 for Windows OS? - Why does a dialog box pop up stating “Another instance of System Console appears to be running with title: SystemConsole” when relaunching the F-Tile Transceiver Toolkit in the Intel® Quartus® Prime Pro Edition Software version 22.1 for Windows OS?
Description After exiting the Transceiver Toolkit and then relaunching it, a dialog box pops up stating “Another instance of System Console appears to be running with title: SystemConsole ”. The device also can’t be reprogrammed over JTAG unless the board is powered down and turned back on. This happens due to the process “quartus_py.exe” not being terminated properly upon exiting the System Console. Resolution This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software version 22.3. To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 22.1 or earlier, manually terminate the process “quartus_py.exe” before relaunching the System Console. To do this, start the Task Manager of Windows and locate “quartus_py.exe” under the “Processes” tab , then click “End Task”.
Custom Fields values:
['novalue']
Troubleshooting
14016541747
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.3
22.1
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-05-23
external_document