Why does the refclk_fgt_enabled_[n] signal on the F-Tile Reference and System PLL Clocks FPGA IP not function as expected in Quartus® Prime Pro Edition Software version 23.2? - Why does the refclk_fgt_enabled_[n] signal on the F-Tile Reference and System PLL Clocks FPGA IP not function as expected in Quartus® Prime Pro Edition Software version 23.2?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.2, the refclk_fgt_enabled_[n] output signal on the F-Tile Reference and System PLL Clocks FPGA IP will always be 1’b0 when you enable monitor mode by setting en_refclk_fgt_[n][1..0] as 2’b11. The refclk_fgt_enabled_[n] signal only functions when the en_refclk_fgt_[n] signal is set to 2’b00 (Disable REFCLK) or 2’b01 (Enable REFCLK). Resolution You should not set the en_refclk_fgt_[n][1..0] signal to 2’b11. If you want to monitor the status of your F-Tile FGT transceiver reference clock, you can infer this by monitoring the tx_pll_locked signal of F-Tile PMA/FEC Direct PHY FPGA IP This problem is fixed in the Quartus® Prime Pro Edition software version 23.3.
Custom Fields values:
['novalue']
Troubleshooting
18030480099
False
['F-Tile Reference and System PLL Clocks IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
23.3
23.2
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-05-01
external_document