Is there a known problem with the per pin RLC value in IBIS files generated in Quartus® Prime Pro Edition Software for Stratix®10 MX devices? - Is there a known problem with the per pin RLC value in IBIS files generated in Quartus® Prime Pro Edition Software for Stratix®10 MX devices?
Description Yes, due to a known problem with Quartus® Prime Pro Edition Software version 20.3 and earlier, when generating an IBIS file for Stratix® 10 MX 1650 and 2100 density devices in UF55 package with "Print per pin RLC package model with mutual coupling' option enabled, the R-value per pin in the generated .ibs file is incorrect. Resolution Download the attached file to obtain the correct per-pin RLC value for Stratix® 10 MX 1650 and 2100 density devices in the UF55 package.
Custom Fields values:
['novalue']
Troubleshooting
18013107783
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
20.3
['Stratix® 10 MX FPGA']
['novalue']
['novalue']
['novalue'] - 2024-11-05
external_document