Self-refresh Not Working Properly for Single-rank DDR3 DIMMs - Self-refresh Not Working Properly for Single-rank DDR3 DIMMs
Description The self-refresh feature does not work properly in simulation or in hardware, for DDR3 registered DIMM designs having Number of chip selects set to 1 and Enable Self-Refresh Control enabled. This issue will be fixed in a future version of the DDR2 and DDR3 SDRAM Controller with UniPHY. Resolution Open the alt_mem_if_nextgen_ddr3_controller_core.v or alt_mem_if_ddr3_controller_top.sv file in an editor and change the following line: .MEM_IF_CKE_WIDTH (MEM_IF_CS_WIDTH), to .MEM_IF_CKE_WIDTH (CTL_CS_WIDTH),
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
11.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document