Why are DFE taps adapted values incorrect in the P-Tile Debug Toolkit ? - Why are DFE taps adapted values incorrect in the P-Tile Debug Toolkit ?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.2, the DFE tap values reported in the P-Tile Debug Toolkit are incorrect. It is always -128 for DFE tap 1 and 0 for DFE tap2 to tap5. Resolution A patch is available to fix this problem for the Intel® Quartus® Prime Pro Edition Software version 21.2. Download and install patch 0.23 from the following links: Intel® Quartus® Prime Pro Edition version 21.2 Patch 0.23 for Windows (.exe) Intel® Quartus® Prime Pro Edition version 21.2 Patch 0.23 for Linux (.run) Readme for Intel® Quartus® Prime Pro Edition version 21.2 Patch 0.23 (.txt) This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.3.
Custom Fields values:
['novalue']
Troubleshooting
1509623792
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
21.3
21.2
['Agilex™ 7 FPGA F-Series', 'Stratix® 10 DX FPGA']
['novalue']
['novalue']
['novalue'] - 2022-02-23
external_document