"Error: Unrecognized switch use-quartus-top-names" while executing ip-setup-simulation command in the Intel® Quartus® Prime Software v21.4 - "Error: Unrecognized switch use-quartus-top-names" while executing ip-setup-simulation command in the Intel® Quartus® Prime Software v21.4
Description Due to a problem in the Intel® Quartus® Prime Pro Software version 21.4, you might encounter the following error while executing command: ip-setup-simulation --use-quartus-top-names --quartus-project=<quartus_project_name>.qpf Error: Unrecognized switch use-quartus-top-names Resolution To work around this problem, follow these steps: Remove " --use-quartus-top-names " switch. Add " set TOP_LEVEL_NAME <top_instance_name> " in run_<simulator>.do of the IP simulation script. This problem has been fixed starting with the version 22.1 of the Intel® Quartus® Prime Pro Software releases.
Custom Fields values:
['novalue']
Troubleshooting
16016749973
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.1
21.4
['Agilex™ 7 FPGAs and SoCs', 'Arria® 10 Bare Die', 'Cyclone® 10 GX FPGA', 'Stratix® FPGAs']
['novalue']
['novalue']
['novalue'] - 2023-10-16
external_document