Why do I see an error in Modelsim when using the Stratix V CUSTOM_PHY IP automatic simulation script in Quartus II Software Version 10.1-SP1? - Why do I see an error in Modelsim when using the Stratix V CUSTOM_PHY IP automatic simulation script in Quartus II Software Version 10.1-SP1? Description Due to a missing line in the simulation script generated by the Stratix® V CUSTOM_PHY IP Megawizard in Quartus II Software Version 10.1-SP1 you will see the following error in Modelsim. # Error in macro .\modelsim_example_script.tcl # can't read "language": no such variable # while executing # "if { == "verilog"} To workaround this error, insert the following at line 68. "set language verilog" This issue will be fixed in a future version of the Quartus® II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Stratix® V FPGAs', 'Stratix® V GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25