Why does the Nios® II build flow report Unable to determine program-size on Windows WSL? - Why does the Nios® II build flow report Unable to determine program-size on Windows WSL? Description Due to a problem in the nios2-elf-stackreport utility in the Intel® Quartus® Prime Pro Edition software version 19.3, the nios2-elf-stackreport utility does not report the program size or the stack heap size. Resolution To work around this problem, edit the nios2-stackreport.pl wrapper to add missing .exe suffix in tool names. Modify file: /nios2eds/bin/nios2-stackreport.pl line 47: “nm” to “nm.exe” line 48: “size” to “size.exe” This problem is fixed beginning with the Intel® Quartus® Prime software version 19.4. Custom Fields values: ['novalue'] Troubleshooting 1808775710 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 19.4 19.3 ['Programmable Logic Devices'] ['Nios® II Embedded Design Suite (EDS)'] ['novalue'] ['novalue'] - 2021-08-25