Error (175001): The Fitter cannot place 1 HSSI_PMA_TX_CGB, which is within Arria 10 Transceiver Native PHY <INSTANCE> - Error (175001): The Fitter cannot place 1 HSSI_PMA_TX_CGB, which is within Arria 10 Transceiver Native PHY <INSTANCE>
Description You may see this error when using the Arria ® 10 device, Native PHY IP in PIPE mode. This is error is due to a mismatch between bonding master setting and physical transceiver channel placement. Resolution To fix this problem modify the bonding master setting in Native PHY IP to match transceiver channel placement. The bonding master should be in physical channel CH1 or CH4. For example, if the following x4 PIPE transceiver channel placement is used, the bonding master is 1. Logical Channel Physical Channel Ch0 GXBL1C_RX_CH3 Ch1 GXBL1C_RX_CH4 Ch2 GXBL1C_RX_CH5 Ch3 GXBL1D_RX_CH0