1.4.1. Enabling Dynamic Reconfiguration to the Ethernet IP - By default, the dynamic reconfiguration is disabled in the eCPRI IP design example and it's only applicable to Stratix 10 (E-tile and H-tile) and Agilex 7 (E-tile) design examples. - 2025-12-29

eCPRI IP Design Example User Guide

Version
24.3
Product Type
Device Families > Agilex Families > Agilex 5
Device Families > Agilex Families > Agilex 5 > D-Series
Device Families > Agilex Families > Agilex 7 > M-Series
Device Families > Agilex Families > Agilex 5 > E-Series
Device Families > Arria Families > Arria 10
Device Families > Agilex Families
Device Families > Agilex Families > Agilex 7 > F-Series
Device Families > Stratix Families > Stratix 10
Device Families > Agilex Families > Agilex 7
Device Families > Arria Families
Device Families > Stratix Families
Device Families > Agilex Families > Agilex 7 > I-Series
Resource Type
Documentation > User Guides
ft:sourceName
DITA
By default, the dynamic reconfiguration is disabled in the eCPRI IP design example and it's only applicable to Stratix® 10 (E-tile and H-tile) and Agilex™ 7 (E-tile) design examples.
  1. Look for the following line in the test_wrapper.sv from the generated <design_example_dir>/simulation/testbench directory:

    parameter ETHERNET_DR_EN = 0

  2. Change the value from 0 to 1:

    parameter ETHERNET_DR_EN = 1