6.10.2. Upgrading the FLEXlm License Manager Server Software - To support network licensing, the Altera® FPGA software requires the FLEXlm license manager server software version 11.19.5.0 or later. - 2026-10-16

Altera® FPGA Software Installation and Licensing

Version
26.1
Product Type
Device Families > Agilex Families > Agilex 5
Device Families > Agilex Families > Agilex 5 > E-Series
Development Software and Tools > AI Development Tools > FPGA AI Suite
Device Families > Cyclone Families > Cyclone IV
Device Families > Agilex Families > Agilex 7
Device Families > Agilex Families > Agilex 3
Development Software and Tools > IP Development Tools > DSP Builder
Device Families > Stratix Families > Stratix IV
Device Families > Stratix Families
Device Families > Stratix Families > Stratix V
Device Families > Agilex Families > Agilex 7 > I-Series
Device Families > Cyclone Families > Cyclone 10
Device Families > Agilex Families > Agilex 7 > M-Series
Development Software and Tools > FPGA Design & Simulation Tools > Quartus Prime Design Software > Pro Edition
Device Families > MAX Families > MAX 10
Device Families > Agilex Families > Agilex 7 > F-Series
Device Families > MAX Families > MAX II
Device Families > Cyclone Families > Cyclone 10 > Cyclone 10 LP
Device Families > Stratix Families > Stratix 10
Development Software and Tools > FPGA Design & Simulation Tools > Quartus Prime Design Software
Device Families > Cyclone Families
Development Software and Tools > Embedded Design Tools & Software > ARM SoC EDS
Device Families > Arria Families
Development Software and Tools > Embedded Design Tools & Software > Nios V
Device Families > MAX Families
Device Families > Agilex Families > Agilex 3 > C-Series
Device Families > Agilex Families
Development Software and Tools > FPGA Design & Simulation Tools > Questa* - Altera FPGA Edition
Device Families > Cyclone Families > Cyclone V
Development Software and Tools > Embedded Design Tools & Software > Intel Simics Simulator for Altera FPGAs
Device Families > Cyclone Families > Cyclone 10 > Cyclone 10 GX
Device Families > Arria Families > Arria V
Device Families > Agilex Families > Agilex 5 > D-Series
Device Families > MAX Families > MAX V
Device Families > Arria Families > Arria II
Device Families > Arria Families > Arria 10
Resource Type
Documentation > User Guides
Documentation > Reference Manual
ft:sourceName
DITA
To support network licensing, the Altera® FPGA software requires the FLEXlm license manager server software version 11.19.5.0 or later. The installation process for Quartus® Prime software installs the FLEXlm software version 11.19.5.0. However, you should also verify that the FLEXlm software version of the license server is 11.19.5.0 or later.
On the license server running the FLEXlm software, type at a command prompt:
Windows*
<FLEXlm system directory>\lmgrd -v
<FLEXlm system directory>\alterad -v
Linux
/<FLEXlm system directory>/lmgrd -v
/<FLEXlm system directory>/alterad -v

Starting from the Quartus® Prime software version 24.1, the version of the lmgrd or alterad daemons is 11.19.5.0. If the lmgrd or alterad daemons on your system are not version 11.19.5.0, you must upgrade both daemons with the versions that the Quartus® Prime software provides.

Note:

You can only have one vendor daemon running at a time on a single system. For example, alterad and saltd can co-exist, but you cannot have two running daemons of alterad. If you have an Altera® FPGA software license and Questa Altera FPGA Edition software license, and also have other Siemens EDA* QuestaSim* software license. You can either merge all of them into a single file or put all Siemens EDA* QuestaSim* software licenses in a single file. If you put all Siemens EDA* QuestaSim* software licenses in a single file, you must remove the VENDOR saltd line from the Altera FPGA software license file. You cannot have Siemens EDA* licenses across two files for the same license server.

If a soft reload through the lmutil lmreread command failed, shut down the current license daemons before reloading them again.

Warning: If your FLEXlm software version is too old, you might observe errors. Refer to https://community.altera.com/kb/knowledge-base/error--flexlm-version-of-vendor-daemon-is-too-old/342390 for more information.

To upgrade an older version of the FLEXlm software:

  1. Make a backup copy of your current lmgrd and alterad daemons.
  2. Copy the new versions of the files to the license server over your current daemons.

    If you installed the FLEXlm software using the Quartus® Prime installer, the current versions of the lmgrd and alterad daemons are in:

    Windows*
    <installation-directory>\quartus\bin64\alterad.exe
    <installation-directory>\quartus\bin64\lmgrd.exe
    Linux
    /<installation-directory>/quartus/linux64/alterad
    <installation-directory>/quartus/linux64/lmgrd
  3. Restart the FLEXlm license server by typing at a command prompt:
    Windows*
    <FLEXlm system directory>\lmutil lmdown -c <license file path>
    <FLEXlm system directory>\lmgrd -c <license file path>[-l <optional log path>]
    Linux
    /<FLEXlm system directory>/lmutil lmdown -c <license file path>
    /<FLEXlm system directory>/lmgrd -c <license file path> [-l <optional log path>]