The IP parameter editor allows you to quickly configure your custom IP variation. Use the following steps to specify IP options and parameters in the Quartus® Prime Pro Edition software.
-
If you do not already have an
Quartus® Prime Pro Edition project in which to integrate your F-Tile Serial Lite IV
IP, you must create one.
- In the Quartus® Prime Pro Edition, click to create a new Quartus Prime project, or to open an existing Quartus Prime project. The wizard prompts you to specify a device.
- Specify the device family Agilex™ 7 and select a production F-Tile device that meets the speed grade requirements for the IP.
- Click Finish.
- In the IP Catalog, locate and select F-Tile Serial Lite IV IP . The New IP Variation window appears.
- Specify a top-level name for your new custom IP variation. The parameter editor saves the IP variation settings in a file named <your_ip> .ip.
- Click OK. The parameter editor appears.
- Specify the parameters for your IP variation. Refer to the Parameter section for information about F-Tile Serial Lite IV IP parameters.
- Optionally, to generate a simulation testbench or compilation and hardware design example, follow the instructions in the Design Example User Guide.
- Click Generate HDL. The Generation dialog box appears.
-
Specify output file generation options, and then click Generate. The IP variation files generate according to your specifications.
- Click Finish. The parameter editor adds the top-level .ip file to the current project automatically. If you are prompted to manually add the .ip file to the project, click to add the file.
- After generating and instantiating your IP variation, make appropriate pin assignments to connect ports and set any appropriate per-instance RTL parameters.