This clock
connection describes multiple IP core instantiations in your
design.
This is a recommended clocking for multiple IP core clock connections.
You must make the following clock connections:
- The i_clk_ref and the i_clk_sys clocks drives all instantiated IP cores.
- The output clock o_clk_pll of a single
IP core can drive all instantiated IP core i_clk_rx and
the i_clk_tx input signals under the following
conditions:
- The shared clock is traceable to a common source reference clock.
- The F-Tile Ethernet Hard IP uses the same rate to configure the its port system clocks.
Figure 23. Clock Connections for Multiple IP Cores
The following are examples of alternative clock sources satisfying the clock
connections requirements:
- Another IP instance's o_clk_pll output clock can drive an IP core specific i_clk_rx and the i_clk_tx input signals provided that their respective reference clocks are configured at the same rate.
- An IO PLL can drive an IP core related input clock signals provided that the PLL and IP core derive their i_clk_ref reference clock from the same reference clock source.
- A GPIO, directly connected to the reference clock, with frequency of 161.1328125 MHz, can directly drive the i_clk_rx and the i_clk_tx input signals.