<?xml version="1.0" encoding="UTF-8"?><MCD declarationType="All" formType="Distribute" ipcStandard="1752-2" version="1.1"><ProductID manufacturingSite="" requesterItemName="" requesterItemNumber="EPF10K130EBC600-2" manufacturerItemName="EPF10K130EBC600-2" manufacturerItemNumber="974543" version=""><AlternateItem comments="" itemName="" itemNumber="" /></ProductID><PIP destination="" fileType="XML" pipIdentifier="2A13" pipVersion="D11.00.00" tpirVersion="01.00" /><Response comments="" date="2019-12-01" docID="" fieldLock="true"><Authorizer email="materialdeclare@intel.com" name="PH Khor" phone="1-800-628-8686" title="Product Ecology Engineer"/><Supplier name="INTEL PSG"><UniqueID authority="" identity="" /></Supplier><Contact email="materialdeclare@intel.com" name="Customer Quality Engineering" phone="1-408-544-7000" title="CQE Engineer"/><Product unitVolume="Each"><Amount unitOfMeasure="g" weight="16.188537997054056"/> <RoHSDeclaration legalDef="RoHS Material Composition Declaration Disclaimer &#13;&#10;- The information provided in this form indicates whether any homogeneous material (as defined by the EU Directive on the Restriction of Hazardous Substances, No. 2011/65/EC, and implemented by the laws of the European Union member states) of the part identified on this form contains lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and/or polybrominated diphenyl ethers (each, a 'RoHS Restricted Substance') in excess of the applicable quantity limit identified above.  If a homogeneous material within the part contains a RoHS Restricted Substance in excess of the applicable quantity limit, Supplier believes that the exemption(s) indicated below apply. &#13;&#10;- The information provided in this form is true and correct to the best of Supplier's knowledge and belief, as of the date that Supplier completes this form. &#13;&#10;- Company acknowledges that Supplier may have relied on information provided by third parties in completing this form, and that Supplier may not have independently verified such information. &#13;&#10;- Supplier accepts no duty to update this form or to notify Company of updates or changes to this form." legalType="Custom" rohsDeclaration="2 - Item(s) contains RoHS restricted substances above the limits per the definition and is not under exemption" supplierAcceptance="true"> <ExemptionList version="ExemptionListVI"><Exemption identity="N/A" /></ExemptionList></RoHSDeclaration><MfgInfo comments="" gridArrayMaterial="Tin/Lead (Sn63Pb37)" maxTime="20" mslRating="3" numberProcessingCycles="3" peakProcessingTemp="220" terminalBaseAlloy="N/A"/><SubItem name="IC"><HomogeneousMaterial name="Ball"><Amount unitOfMeasure="g" weight="1.222635656595230" /><SubstanceCategory jigLevel="A" name="Bump 2"><Substance cas="7439-92-1" name="Pb"><Amount ppm="370000" unitOfMeasure="g" weight="0.452375203371048" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Bump"><Substance cas="7440-31-5" name="Sn"><Amount ppm="630000" unitOfMeasure="g" weight="0.770260453224182" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Dam"><Amount unitOfMeasure="g" weight="0.016016999725252" /><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="60676-86-0" name="SiO2"><Amount ppm="720000" unitOfMeasure="g" weight="0.011532239615917" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Resin"><Substance cas="Not applicable" name="Bis A + Bis F"><Amount ppm="280000" unitOfMeasure="g" weight="0.004484760109335" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die"><Amount unitOfMeasure="g" weight="0.117855932395742" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7429-90-5" name="Aluminum"><Amount ppm="1200" unitOfMeasure="g" weight="0.000141427124618" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-21-3" name="Silicon"><Amount ppm="987880" unitOfMeasure="g" weight="0.116427518427372" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secrect" name="silicon compounds"><Amount ppm="10000" unitOfMeasure="g" weight="0.001178559381515" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-32-6" name="Titanium"><Amount ppm="500" unitOfMeasure="g" weight="0.000058927969803" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-33-7" name="Tungsten"><Amount ppm="400" unitOfMeasure="g" weight="0.000047142373660" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Copper alloys"><Substance cas="7440-50-8" name="Copper"><Amount ppm="20" unitOfMeasure="g" weight="0.000002357118774" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die Attach"><Amount unitOfMeasure="g" weight="0.023606317583472" /><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="7440-22-4" name="Ag"><Amount ppm="750000" unitOfMeasure="g" weight="0.017704738304019" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Resin"><Substance cas="Trade secret" name="Resin"><Amount ppm="250000" unitOfMeasure="g" weight="0.005901579279453" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Encapsulant"><Amount unitOfMeasure="g" weight="0.592480555176735" /><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="60676-86-0" name="SiO2"><Amount ppm="740000" unitOfMeasure="g" weight="0.438435614109039" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Resin"><Substance cas="Not applicable" name="Epoxy"><Amount ppm="260000" unitOfMeasure="g" weight="0.154044941067696" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Heat Spreader"><Amount unitOfMeasure="g" weight="13.121908187866211" /><SubstanceCategory jigLevel="Supplier" name="Cu foil 1"><Substance cas="7440-50-8" name="Cu"><Amount ppm="1000000" unitOfMeasure="g" weight="13.121908187866211" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Heat Spreader Adhesive"><Amount unitOfMeasure="g" weight="0.134826471097767" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Addition"><Amount ppm="200000" unitOfMeasure="g" weight="0.026965294033289" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Epoxy Resin"><Amount ppm="400000" unitOfMeasure="g" weight="0.053930588066578" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Hardener"><Amount ppm="50000" unitOfMeasure="g" weight="0.006741323508322" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Thermoplastic resin"><Amount ppm="350000" unitOfMeasure="g" weight="0.047189265489578" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Heat Spreader Plating"><Amount unitOfMeasure="g" weight="0.372708946466446" /><SubstanceCategory jigLevel="B" name="Ni plating"><Substance cas="7440-02-0" name="Ni"><Amount ppm="1000000" unitOfMeasure="g" weight="0.372708946466446" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Metal Layer"><Amount unitOfMeasure="g" weight="0.270879317075014" /><SubstanceCategory jigLevel="B" name="Ni plating"><Substance cas="7440-02-0" name="Ni"><Amount ppm="48546" unitOfMeasure="g" weight="0.013150198385119" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Au plating"><Substance cas="7440-57-5" name="Au"><Amount ppm="73692" unitOfMeasure="g" weight="0.019961705431342" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Cu foil 1"><Substance cas="7440-50-8" name="Cu"><Amount ppm="877761" unitOfMeasure="g" weight="0.237767413258553" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Tape"><Amount unitOfMeasure="g" weight="0.308900382835418" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="25085-75-0" name="Phenol resin"><Amount ppm="17937" unitOfMeasure="g" weight="0.005540813785046" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="25038-59-9" name="Poly-ethylene-terephthalate"><Amount ppm="100448" unitOfMeasure="g" weight="0.031028557568789" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secret" name="Polyamide resin"><Amount ppm="25112" unitOfMeasure="g" weight="0.007757139392197" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Polyimide"><Amount ppm="659193" unitOfMeasure="g" weight="0.203624919056892" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Soldermask"><Amount ppm="197309" unitOfMeasure="g" weight="0.060948953032494" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Wire"><Amount unitOfMeasure="g" weight="0.006719230236769" /><SubstanceCategory jigLevel="B" name=""><Substance cas="7440-41-7" name="Be"><Amount ppm="10" unitOfMeasure="g" weight="0.000000067192303" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-70-2" name="Ca"><Amount ppm="30" unitOfMeasure="g" weight="0.000000201576910" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Au plating"><Substance cas="7440-57-5" name="Au"><Amount ppm="999930" unitOfMeasure="g" weight="0.006718759890646" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="7440-22-4" name="Ag"><Amount ppm="30" unitOfMeasure="g" weight="0.000000201576910" /></Substance></SubstanceCategory></HomogeneousMaterial></SubItem></Product></Response></MCD>