<?xml version="1.0" encoding="UTF-8"?><MCD declarationType="All" formType="Distribute" ipcStandard="1752-2" version="1.1"><ProductID manufacturingSite="" requesterItemName="" requesterItemNumber="EP4CGX30BF14C8" manufacturerItemName="EP4CGX30BF14C8" manufacturerItemNumber="973218" version=""><AlternateItem comments="" itemName="" itemNumber="" /></ProductID><PIP destination="" fileType="XML" pipIdentifier="2A13" pipVersion="D11.00.00" tpirVersion="01.00" /><Response comments="" date="2019-12-01" docID="" fieldLock="true"><Authorizer email="materialdeclare@intel.com" name="PH Khor" phone="1-800-628-8686" title="Product Ecology Engineer"/><Supplier name="INTEL PSG"><UniqueID authority="" identity="" /></Supplier><Contact email="materialdeclare@intel.com" name="Customer Quality Engineering" phone="1-408-544-7000" title="CQE Engineer"/><Product unitVolume="Each"><Amount unitOfMeasure="g" weight="0.645671843822645"/> <RoHSDeclaration legalDef="RoHS Material Composition Declaration Disclaimer &#13;&#10;- The information provided in this form indicates whether any homogeneous material (as defined by the EU Directive on the Restriction of Hazardous Substances, No. 2011/65/EC, and implemented by the laws of the European Union member states) of the part identified on this form contains lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and/or polybrominated diphenyl ethers (each, a 'RoHS Restricted Substance') in excess of the applicable quantity limit identified above.  If a homogeneous material within the part contains a RoHS Restricted Substance in excess of the applicable quantity limit, Supplier believes that the exemption(s) indicated below apply. &#13;&#10;- The information provided in this form is true and correct to the best of Supplier's knowledge and belief, as of the date that Supplier completes this form. &#13;&#10;- Company acknowledges that Supplier may have relied on information provided by third parties in completing this form, and that Supplier may not have independently verified such information. &#13;&#10;- Supplier accepts no duty to update this form or to notify Company of updates or changes to this form." legalType="Custom" rohsDeclaration="2 - Item(s) contains RoHS restricted substances above the limits per the definition and is not under exemption" supplierAcceptance="true"> <ExemptionList version="ExemptionListVI"><Exemption identity="N/A" /></ExemptionList></RoHSDeclaration><MfgInfo comments="" gridArrayMaterial="Tin/Lead (Sn63Pb37)" maxTime="20" mslRating="3" numberProcessingCycles="3" peakProcessingTemp="235" terminalBaseAlloy="N/A"/><SubItem name="IC"><HomogeneousMaterial name="Ball"><Amount unitOfMeasure="g" weight="0.211489744484424" /><SubstanceCategory jigLevel="A" name=""><Substance cas="7439-92-1" name="Pb"><Amount ppm="370000" unitOfMeasure="g" weight="0.078251205384731" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-31-5" name="Sn"><Amount ppm="630000" unitOfMeasure="g" weight="0.133238539099693" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die #1"><Amount unitOfMeasure="g" weight="0.025594199573987" /><SubstanceCategory jigLevel="B" name=""><Substance cas="7440-02-0" name="Nickel (Ni)"><Amount ppm="10" unitOfMeasure="g" weight="0.000000255942012" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7429-90-5" name="Aluminum (Al)"><Amount ppm="1000" unitOfMeasure="g" weight="0.000025594199542" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Copper (Cu)"><Amount ppm="2500" unitOfMeasure="g" weight="0.000063985498855" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-21-3" name="Silicon"><Amount ppm="986090" unitOfMeasure="g" weight="0.025238184258342" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secret" name="Silicon and compounds"><Amount ppm="10000" unitOfMeasure="g" weight="0.000255941995420" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-25-7" name="Tantalum (Ta)"><Amount ppm="200" unitOfMeasure="g" weight="0.000005118839908" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-33-7" name="Tungsten (W)"><Amount ppm="200" unitOfMeasure="g" weight="0.000005118839908" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die Attach #1"><Amount unitOfMeasure="g" weight="0.003838420117973" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="2082-81-7" name="1,4-Butanediol dimethacrylate"><Amount ppm="100000" unitOfMeasure="g" weight="0.000383842008887" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="60676-86-0" name="SiO2"><Amount ppm="900000" unitOfMeasure="g" weight="0.003454578109086" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Laminate"><Amount unitOfMeasure="g" weight="0.148572927735587" /><SubstanceCategory jigLevel="B" name="Cu foil"><Substance cas="7440-38-2" name="Arsenic"><Amount ppm="51" unitOfMeasure="g" weight="0.000007541997547" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="B" name="Ni plating"><Substance cas="7440-02-0" name="Ni"><Amount ppm="45808" unitOfMeasure="g" weight="0.006805758457631" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Au plating"><Substance cas="7440-57-5" name="Au"><Amount ppm="7976" unitOfMeasure="g" weight="0.001184976426885" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Cu foil"><Substance cas="7440-50-8" name="Cu"><Amount ppm="126857" unitOfMeasure="g" weight="0.018847452476621" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 1"><Substance cas="65997-17-3" name="Glass fiber"><Amount ppm="324132" unitOfMeasure="g" weight="0.048157200217247" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 2"><Substance cas="105391-33-1" name="BIS(3-ETHYL-5-METHYL-4-MALEIMIDOPHENYL)METHANE"><Amount ppm="64779" unitOfMeasure="g" weight="0.009624435566366" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 3"><Substance cas="9003-36-5" name="Phenolic Polymer Resin, Epikote 155"><Amount ppm="64779" unitOfMeasure="g" weight="0.009624435566366" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 4"><Substance cas="1156-51-0" name="Triazine"><Amount ppm="64779" unitOfMeasure="g" weight="0.009624435566366" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 5"><Substance cas="21645-51-2" name="Aluminium hydroxide"><Amount ppm="97310" unitOfMeasure="g" weight="0.014457667246461" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 6"><Substance cas="Trade secret" name="Other inoranic filler"><Amount ppm="97310" unitOfMeasure="g" weight="0.014457667246461" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Laminate 7"><Substance cas="80-05-7" name="Bisphenol A"><Amount ppm="7203" unitOfMeasure="g" weight="0.001070159953088" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 1"><Substance cas="Trade secret" name="Proprietary Material-Cured resin"><Amount ppm="60994" unitOfMeasure="g" weight="0.009062097407877" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 2"><Substance cas="7727-43-7" name="Barium sulfate"><Amount ppm="30794" unitOfMeasure="g" weight="0.004575182218105" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 3"><Substance cas="14807-96-6" name="Talc (Mg3H2(SiO3)4)"><Amount ppm="3565" unitOfMeasure="g" weight="0.000529603101313" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 4"><Substance cas="147-14-8" name="Copper phthalocyanine bule"><Amount ppm="198" unitOfMeasure="g" weight="0.000029422393709" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 5"><Substance cas="60676-86-0" name="Silicon dioxide (SiO2)"><Amount ppm="891" unitOfMeasure="g" weight="0.000132400775328" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 6"><Substance cas="Trade secret" name="Other aluminium compounds"><Amount ppm="198" unitOfMeasure="g" weight="0.000029422393709" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Solder Mask 7"><Substance cas="Trade secret" name="Other miscellaneous substances"><Amount ppm="2376" unitOfMeasure="g" weight="0.000353068724507" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Mold Compound"><Amount unitOfMeasure="g" weight="0.253071496030316" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="1333-86-4" name="Carbon Black"><Amount ppm="5000" unitOfMeasure="g" weight="0.001265357481316" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secret" name="Metal hydroxide"><Amount ppm="30000" unitOfMeasure="g" weight="0.007592144887894" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="9003-35-4" name="Phenol Novolac"><Amount ppm="40000" unitOfMeasure="g" weight="0.010122859850526" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="60676-86-0" name="SiO2"><Amount ppm="875000" unitOfMeasure="g" weight="0.221437558531761" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Resin"><Substance cas="Trade secret" name="Epoxy resins"><Amount ppm="50000" unitOfMeasure="g" weight="0.012653575278819" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Wire"><Amount unitOfMeasure="g" weight="0.003105055880358" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-22-4" name="Ag"><Amount ppm="10" unitOfMeasure="g" weight="0.000000031050558" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Cu"><Amount ppm="978970" unitOfMeasure="g" weight="0.003039756556973" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Others"><Amount ppm="20" unitOfMeasure="g" weight="0.000000062101115" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-05-3" name="Pd"><Amount ppm="21000" unitOfMeasure="g" weight="0.000065206171712" /></Substance></SubstanceCategory></HomogeneousMaterial></SubItem></Product></Response></MCD>