<?xml version="1.0" encoding="UTF-8"?><MCD declarationType="All" formType="Distribute" ipcStandard="1752-2" version="1.1"><ProductID manufacturingSite="" requesterItemName="" requesterItemNumber="EPC16UI88N" manufacturerItemName="EPC16UI88N" manufacturerItemNumber="971256" version=""><AlternateItem comments="" itemName="" itemNumber="" /></ProductID><PIP destination="" fileType="XML" pipIdentifier="2A13" pipVersion="D11.00.00" tpirVersion="01.00" /><Response comments="" date="2019-12-01" docID="" fieldLock="true"><Authorizer email="materialdeclare@intel.com" name="PH Khor" phone="1-800-628-8686" title="Product Ecology Engineer"/><Supplier name="INTEL PSG"><UniqueID authority="" identity="" /></Supplier><Contact email="materialdeclare@intel.com" name="Customer Quality Engineering" phone="1-408-544-7000" title="CQE Engineer"/><Product unitVolume="Each"><Amount unitOfMeasure="g" weight="0.205033545931508"/> <RoHSDeclaration legalDef="RoHS Material Composition Declaration Disclaimer &#13;&#10;- The information provided in this form indicates whether any homogeneous material (as defined by the EU Directive on the Restriction of Hazardous Substances, No. 2011/65/EC, and implemented by the laws of the European Union member states) of the part identified on this form contains lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls and/or polybrominated diphenyl ethers (each, a 'RoHS Restricted Substance') in excess of the applicable quantity limit identified above.  If a homogeneous material within the part contains a RoHS Restricted Substance in excess of the applicable quantity limit, Supplier believes that the exemption(s) indicated below apply. &#13;&#10;- The information provided in this form is true and correct to the best of Supplier's knowledge and belief, as of the date that Supplier completes this form. &#13;&#10;- Company acknowledges that Supplier may have relied on information provided by third parties in completing this form, and that Supplier may not have independently verified such information. &#13;&#10;- Supplier accepts no duty to update this form or to notify Company of updates or changes to this form." legalType="Custom" rohsDeclaration="1 - Item(s) does not contain RoHS restricted substances per the definition above" supplierAcceptance="true"> <ExemptionList version="ExemptionListVI"><Exemption identity="N/A" /></ExemptionList></RoHSDeclaration><MfgInfo comments="" gridArrayMaterial="Tin/Silver/Copper (Sn/Ag/Cu)" maxTime="30" mslRating="3" numberProcessingCycles="3" peakProcessingTemp="260" terminalBaseAlloy="N/A"/><SubItem name="IC"><HomogeneousMaterial name="Ball"><Amount unitOfMeasure="g" weight="0.035244369311840" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-22-4" name="Ag"><Amount ppm="30000" unitOfMeasure="g" weight="0.001057331101038" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Cu"><Amount ppm="5000" unitOfMeasure="g" weight="0.000176221845322" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-31-5" name="Sn"><Amount ppm="965000" unitOfMeasure="g" weight="0.034010816365480" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die #1"><Amount unitOfMeasure="g" weight="0.006035039953190" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7429-90-5" name="Aluminum"><Amount ppm="4000" unitOfMeasure="g" weight="0.000024140159439" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Copper"><Amount ppm="20" unitOfMeasure="g" weight="0.000000120700804" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-21-3" name="Silicon"><Amount ppm="983880" unitOfMeasure="g" weight="0.005937755107880" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secrect" name="silicon compounds"><Amount ppm="10000" unitOfMeasure="g" weight="0.000060350401327" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-32-6" name="Titanium"><Amount ppm="2000" unitOfMeasure="g" weight="0.000012070079720" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-33-7" name="Tungsten"><Amount ppm="100" unitOfMeasure="g" weight="0.000000603504020" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Die attach #1"><Amount unitOfMeasure="g" weight="0.001071994964149" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-22-4" name="Ag"><Amount ppm="780000" unitOfMeasure="g" weight="0.000836156075820" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Trade secret" name="Resin"><Amount ppm="220000" unitOfMeasure="g" weight="0.000235838888329" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Laminate"><Amount unitOfMeasure="g" weight="0.043905352200567" /><SubstanceCategory jigLevel="B" name=""><Substance cas="7440-38-2" name="Arsenic"><Amount ppm="43" unitOfMeasure="g" weight="0.000001867085416" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="B" name=""><Substance cas="7440-02-0" name="Ni"><Amount ppm="163090" unitOfMeasure="g" weight="0.007160538807511" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-57-5" name="Au"><Amount ppm="12989" unitOfMeasure="g" weight="0.000570276693907" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="68541-56-0" name="Bromophenol,formaldehyde,epichlorohydrin polymer"><Amount ppm="28561" unitOfMeasure="g" weight="0.001254000002518" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Cu"><Amount ppm="106271" unitOfMeasure="g" weight="0.004665846470743" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Laminate"><Amount ppm="542667" unitOfMeasure="g" weight="0.023825999349356" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="Solder Mask"><Amount ppm="146379" unitOfMeasure="g" weight="0.006426823791116" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Mold Compound"><Amount unitOfMeasure="g" weight="0.118170796893537" /><SubstanceCategory jigLevel="Supplier" name="Filler"><Substance cas="60676-86-0" name="SiO2"><Amount ppm="885000" unitOfMeasure="g" weight="0.104581154882908" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name="Resin"><Substance cas="Trade secret" name="Biphenyl"><Amount ppm="115000" unitOfMeasure="g" weight="0.013589642010629" /></Substance></SubstanceCategory></HomogeneousMaterial><HomogeneousMaterial name="Wire"><Amount unitOfMeasure="g" weight="0.000605992608225" /><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-22-4" name="Ag"><Amount ppm="25" unitOfMeasure="g" weight="0.000000015149814" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-57-5" name="Au"><Amount ppm="990000" unitOfMeasure="g" weight="0.000599932682235" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-70-2" name="Ca"><Amount ppm="20" unitOfMeasure="g" weight="0.000000012119852" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-50-8" name="Cu"><Amount ppm="5" unitOfMeasure="g" weight="0.000000003029963" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7439-89-6" name="Fe"><Amount ppm="5" unitOfMeasure="g" weight="0.000000003029963" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7439-95-4" name="Mg"><Amount ppm="5" unitOfMeasure="g" weight="0.000000003029963" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="Not applicable" name="other"><Amount ppm="40" unitOfMeasure="g" weight="0.000000024239704" /></Substance></SubstanceCategory><SubstanceCategory jigLevel="Supplier" name=""><Substance cas="7440-05-3" name="Pd"><Amount ppm="9900" unitOfMeasure="g" weight="0.000005999326731" /></Substance></SubstanceCategory></HomogeneousMaterial></SubItem></Product></Response></MCD>